Automatic Urinal Flusher KEG-1033AD

  • Brand: KEGE
  • 2s for pre-flush & 6s for after-flush
  • Automatically flush if no usage in 24 hours
  • Stainless steel face panel and all copper solenoid valve


Features:

  • Automatic on/off: when you stand in front of the auto urinal flush, 2s pre-flush after detection; 6s Flush automatically after leaving.
  • Automatically flush if no usage in 24 hours.
  • Low power indication: This may indicate it is time to replace existing batteries with new ones or there is not enough power going to the unit.
  • Water-saving: Water-efficient flush valve reduces overall water usage without sacrificing water.
  • Energy-saving: 4AA alkaline batteries shall last approximately 3000 times/month for 1.5 to 2 years.
  • Installation of concealed wall mount type, straight up and down, suitable for wall installation above 10cm thick.
  • Healthy and Safe: Touch free, it can prevent the spread of bacteria and germs, convenience and hygiene.
  • Stainless steel box, all copper solenoid valve: electronic part seal design, waterproof and moisture-proof.

Auto Urinal Flusher KEG-1033AD
Urinal auto flush structure
Auto Urinal Flusher KEG-1033AD installation diagram

Auto Urinal Flusher Valve KEG-1033AD Specification

External Power Supply Applicable water pressure Applicable Water Temperature Ambient Temperature Feedwater caliber Flushing water volume
4XAA batteries

AC:110v-240V,50Hz-60Hz DC&AC combined 0.05-0.7Mpa 0.1-60℃ 0.1-45℃ G1/2” 1.5-4L(10s based on water pressure of 0.3-0.6Mpa)

How to install automatic urinal flush?

STEP1

Dig a suitable hole on the wall according to the installation instruction. Inter control box into the wall and connect the inlet pipe and outlet pipe. Open the stop-valve to ensure all the connectors are watertight.

Notice:
The distance between the housing surface and the ceramic tiles should be longer than 15mm.

STEP1

STEP2

Adjust the position of the control box, fixed with pieces of wood or other fillers. Then cover the control box by protecting board to avoid the solenoid valve be damaged when filling the cement around the control box. Finally, laying the tiles.

Notice:
The protecting board should be taken down when finished.

STEP2
Auto urinal valve installation step3
Auto urinal valve installation step4

STEP3

1. A wire connected to the 220V power source should be laid before placing the control box into the wall.
2. Connect the connectors as shown right, place the power supply box as figure 1 shows.
3. Connect the power supply box to the power source.
4. Fix the auto urinal flush face plate on the control box.

Notice:
Please shut off the power source during the installation.

STEP3

Touchless Urinal Flusher Valve Troubleshooting

Problem Possible Reason Suggested Solution
No water flow Batteries run out Replace batteries
Dirt on sensor surface Clean the sensor surface
Main water supply is shut off Turn main water supply on
Dirt on water filter net Clean the water filter net
Water pressure is not applicable Refer to technical specification
Have a continuous water flow problem Batteries run out Replace batteries
Low water pressure Refer to technical specification

Auto urinal flusher can be used in public toilets, hospitals, shopping malls, airports, restaurants, schools and so on.

People who are asking more: