Automatic Urinal Flusher KEG-1022AD

The automatic urinal flush KEG-1022AD is an auto urinal flush valve that integrates electronic sensors, valves, and control processes together. It uses active infrared automatic sensor technology. When you stand in front of the auto flush valve, 2s pre-flush after detection; 6s Flush automatically after leaving. The sensor is integrated inside the valve. A means AC power which can use a power adapter plug to connect alternating current. D means DC with 4 AA 6V alkaline batteries

  • Brand: KEGE
  • Item No: KEG-1022AD
  • 2s for pre-flush & 6s for after-flush
  • Automatically flush if no usage in 24 hours
  • Hygienic, bacteria and germs free without touching
  • ABS plastic face panel and all copper solenoid valve


Features:

  • Automatic on/off: when you stand in front of the auto urinal flush, 2s pre-flush after detection; 6s Flush automatically after leaving.
  • Automatically flush if no usage in 24 hours.
  • Low power indication: This may indicate it is time to replace existing batteries with new ones or there is not enough power going to the unit.
  • Water-saving: Water-efficient flusher valve reduces overall water usage without sacrificing water.
  • Energy-saving: 4AA alkaline batteries shall last approximately 3000 times/month for 1.5 to 2 years.
  • Installation of concealed wall type, straight up and down, suitable for wall installation above 10cm thick.
  • Healthy and Safe: Touch free, it can prevent the spread of bacteria and germs, convenience and hygiene.
  • Stainless steel box, all copper solenoid valve: electronic part seal design, waterproof and moisture-proof.

Auto Urinal Flusher KEG-1022AD
Urinal auto flush structure
Auto Urinal Flusher Valve KEG-1022AD installation diagram

Auto Urinal Flusher Valve KEG-1022AD Specification

External Power Supply Applicable water pressure Applicable Water Temperature Ambient Temperature Feedwater caliber Flushing water volume
4XAA batteries

AC:110v-240V,50Hz-60Hz DC&AC combined 0.05-0.7Mpa 0.1-60℃ 0.1-45℃ G1/2” 1.5-4L(10s based on water pressure of 0.3-0.6Mpa)

Motion sensor for Automatic Urinal Flusher

As the most important part, the work of the sensor is to forward the signals to the valve to turn on the urinal flusher after detecting your body. Its job is to inform the valve when to turn on or off the water when your body comes and leaves. The cover of the sensor is made by plastic ABS or PA and there is an electronic circuit board inside the sensor eye which also includes the led light.

Normally the sensor eye is placed on the metal faceplate. Mostly the plate is made by stainless steel, some may using cheaper plastic material.

Automatic Urinal Flush Sensor KEG-K1022

Normally the material of the sensor cover is plastic ABS or PA, the infrared beams can pass through it. Kege have about 50 types of the different sensor head for the selection. We can also customize the sensor cover according to your products.

Infrared Sensor Head Optional

How to install automatic urinal flush?

STEP1

Dig a suitable hole on the wall according to the installation instruction. Inter control box into the wall and connect the inlet pipe and outlet pipe. Open the stop-valve to ensure all the connectors are watertight.

Notice:
The distance between the housing surface and the ceramic tiles should be longer than 15mm.

Auto urinal valve installation step1

STEP2

Adjust the position of the control box, fixed with pieces of wood or other fillers. Then cover the control box by protecting board to avoid the solenoid valve be damaged when filling the cement around the control box. Finally, laying the tiles.

Notice:
The protecting board should be taken down when finished.

Auto urinal valve installation step2
Auto urinal valve installation step3
Auto urinal valve installation step4

STEP3

1. A wire connected to the 220V power source should be laid before placing the control box into the wall.
2. Connect the connectors as shown right, place the power supply box as figure 1 shows.
3. Connect the power supply box to the power source.
4. Fix the auto urinal flush face plate on the control box.

Notice:
Please shut off the power source during the installation.

Auto urinal valve installation last step

Auto Urinal Flusher Valve Troubleshooting

Problem Possible Reason Suggested Solution
No water flow Batteries run out Replace batteries
Dirt on sensor surface Clean the sensor surface
Main water supply is shut off Turn main water supply on
Dirt on water filter net Clean the water filter net
Water pressure is not applicable Refer to technical specification
Have a continuous water flow problem Batteries run out Replace batteries
Low water pressure Refer to technical specification

Auto urinal flushers can be used in public toilets, hospitals, shopping malls, airports, restaurants, schools and so on.

People who are asking more:

Automatic urinal flusher uses infrared sensor technology that when you stand in front of urinal ceramic, the sensor detects and gives a pulse signal to the solenoid valve to open and give 2s pre-flush, then stop. After you leave, again 6s flush automatically. Program control all the process.

For more details, please click here.

Auto urinal flushers need electricity for sure. Both the sensor and solenoid valve works need electricity power. Normally DC: 4xAA alkaline 6V batteries.

6V with 4xAA alkaline batteries shall last approximately 3000 times/month for one year.

You can activate a flush by holding the palm of your hand up to the sensor for a few seconds before taking it away.

Related products:

Related articles: